Preparation for Scanning Dell EMC VNX
StorageGuard collects configuration data from EMC VNX storage systems by running read-only NaviSECCLI commands on a storage management host installed with Navisphere CLI.
The following table lists the requirements for scanning EMC VNX / CLARiiON systems:
# | Description |
1 | Provide the network name or IP address of NaviCLI proxy hosts. |
2 | Provide a user account (and password) for each NaviCLI proxy host. |
3 | Provide the network name or IP address for SP A of each VNX / CLARiiON storage system. |
4 | Provide an array user account (and password) for each VNX / CLARiiON storage system |
5 | The user account should be assigned with an unlimited read-only role. Examples of read-only commands used:
|
6 | Verify IP connectivity through SSH (default is port 22) is available between the StorageGuard server and each NaviCLI proxy. |
7 | Verify IP connectivity is available between the NaviCLI proxy and each VNX array that it scans. |
Creating a User Account for Scanning Dell EMC VNX
The following suggested method can be used to create a user account with appropriate privileges:
naviseccli -address <SP A IP> security -adduser -user cntuser -password <password> -scope global -role Monitor
Comments
0 comments
Please sign in to leave a comment.